If you need urgent consulting help click here

INA219 Bidirectional Power/Current Monitor

Overview

This sample application measures shunt voltage, bus voltage, power and current every 2 seconds and prints them to console. The calibration/configuration parameters can be set in the devicetree file.

References

Wiring

The supply voltage of the INA219 can be in the 3V to 5.5V range. The common mode voltage of the measured bus can be in the 0V to 26V range.

Building and Running

# From the root of the zephyr repository
west build -b blackpill_f411ce samples/sensor/ina219
west flash

Sample Output

When monitoring a 3.3 V bus with a 0.1 Ohm shunt resistor you should get a similar output as below, repeated every 2 seconds:

Shunt: 0.001570 [V] -- Bus: 3.224000 [V] -- Power: 0.504000 [W] -- Current: 0.157000 [A]

A negative sign indicates current flowing in reverse direction:

Shunt: -0.001560 [V] -- Bus: 3.224000 [V] -- Power: 0.502000 [W] -- Current: -0.156000 [A]